SIMATIC MP 277 10" KEY MULTIPANEL W. RETENTIVE MEMORY 10,4" TFT DISPLAY 6 MB USER MEMORY CONFIG. WINCC FLEXIBLE 2005 STANDARD SP1 ******************************* THIS PRODUCT IS NO LONGER AVAILABLE FROM OCT. 1ST, 2014. INFORMATION ABOUT SUCCESSOR SEE SIMATIC UPDATE ID: 62977695 FOR FURTHER QUESTIONS PLEASE APPROACH YOUR SIEMENS CONTACT PERSON. |
General information |
Customer-specific configuration |
Yes |
Display |
Design of display |
TFT |
Screen diagonal |
10.4 in |
Size |
10.4" |
Display type |
TFT, 65536 colors |
Number of grayscales |
0 |
Color type |
Colors |
Resolution (pixels) |
● Horizontal image resolution |
640 |
● Vertical image resolution |
480 |
● Resolution (WxH in pixel) |
640 x 480 |
Backlighting |
● MTBF backlighting (at 25 °C) |
50 000 h |
Control elements |
Control elements |
Membrane keyboard |
Operating options |
Keys |
Function keys, programmable |
36 function keys, 28 with LEDs |
Connection for mouse/keyboard/barcode reader |
USB / USB / USB |
Keyboard |
● Keys with LED |
Yes |
● freely inscribable membrane keys |
Yes |
● Number of function keys with LEDs |
28 |
— Multi-key operation |
Yes |
— Number of multi-key operations |
2 |
● Numeric/alphabetical input |
Yes / Yes |
● Multi-key operation |
Yes |
Touch operation |
● Design as touch screen |
No |
Supply voltage |
Type of supply voltage |
DC |
Processor |
Processor |
ARM |
Memory |
Usable memory for user data |
6 Mbyte |
Main memory |
|
● Capacity of main memory, maximum |
64 Mbyte |
Time of day |
Clock |
● Type |
Hardware clock, battery backup, synchronizable |
● Hardware clock (real-time clock) |
Yes |
● Battery-backed |
Yes |
● Synchronizable |
Yes |
Interfaces |
Interfaces |
1 x RS422, 1 x RS485, 1 x Ethernet (RJ45) |
Number of RS 485 interfaces |
1 |
USB port |
2 x USB |
Multi Media Card slot |
1x Multimedia Card slot, up to 128 MB |
Industrial Ethernet |
● Industrial Ethernet interface |
1 x Ethernet (RJ45) |
Protocols |
Supports protocol for PROFIsafe |
No |
PROFIBUS |
Yes |
Protocols (Ethernet) |
● TCP/IP |
Yes |
Further protocols |
● other bus systems |
Yes |
Degree and class of protection |
Front |
IP65, NEMA 4x (when installed) |
IP (at the front) |
IP65 |
IP (rear) |
IP20 |
Standards, approvals, certificates |
Certifications |
CE, FM Class I Div. 2, UL, cULus, EX Zone 22, NEMA 4x (Enclosure Type 4X, Type 12) |
cULus |
Yes |
Suitable for safety functions |
No |
Use in hazardous areas |
● EX zone 22 |
Yes |
● FM Class I Division 2 |
Yes |
Ambient conditions |
Mounting position |
vertical |
maximum permissible angle of inclination without external ventilation |
+/- 35 ° |
Operating temperature |
● Operation |
0 °C to +50 °C |
Storage/transport temperature |
● Transport, storage |
-20 °C to +60 °C |
Relative humidity |
● Operation, max. |
90 % |
Operating systems |
Operating system |
Windows CE |
Configuration |
Message indicator |
Yes |
With alarm logging system (incl. buffer and acknowledgment) |
Yes |
Process value display (output) |
Yes |
Process value default (input) possible |
Yes |
Recipe administration |
Yes |
Configuration software |
● STEP 7 Basic (TIA Portal) |
No |
● STEP 7 Professional (TIA Portal) |
No |
● WinCC flexible Compact |
No |
● WinCC flexible Standard |
Yes |
● WinCC flexible Advanced |
Yes |
● WinCC Basic (TIA Portal) |
No |
● WinCC Comfort (TIA Portal) |
Yes |
● WinCC Advanced (TIA Portal) |
Yes |
● WinCC Professional (TIA Portal) |
Yes |
● Configuration tool |
WinCC flexible Standard Version 2005 SP1 or higher (to be ordered separately) |
● 2nd configuration kit |
WinCC flexible Standard |
— Version |
Version 2005 SP 1 |
— Configuration tool |
WinCC flexible |
— Type |
Standard |
Languages |
Online languages |
● Number of online/runtime languages |
16 |
Languages |
● Languages per project |
32 |
Functionality under WinCC (TIA Portal) |
Libraries |
Yes |
Task planner |
Yes |
Help system |
Yes |
● Number of characters per info text |
80 |
Message system |
● Number of alarm classes |
32 |
● Number of messages |
4 000 |
● Bit messages |
Yes |
● Analog messages |
Yes |
● Number of bit messages |
4 000 |
● Number of analog messages |
200 |
● System messages HMI |
Yes |
● System messages PLC |
Yes |
● System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.) |
Yes |
● Message length (in characters) |
80 |
● Lines |
1 |
● Number of process values per message |
8 |
● Acknowledgment groups |
Yes |
● Message indicator |
Yes |
● First/last value |
Yes |
Recipe administration |
● Number of recipes |
300 |
● Data records per recipe |
500 |
● Entries per data record |
1 000 |
● Recipe memory |
64 KB integrated Flash, expandable |
Variables |
● Number of variables per device |
2 048 |
● Number of variables per screen |
200 |
● Number of variables |
1 000 |
● Initial values |
2 048 |
● Limit values |
Yes |
● Multiplexing |
Yes |
● Structs |
Yes |
● Type Date & Time |
2 048 |
Images |
● Number of configurable images |
500 |
● Permanent window/default |
Yes |
● Start screen configurable |
Yes |
● Image selection by PLC |
Yes |
● Image number in the PLC |
Yes |
Image objects |
● Text objects |
10,000 text elements |
● Fields per image |
200 |
● Date/time fields |
200 |
● Return |
Yes |
● Graphics object |
Bit maps, icons, vector graphics |
— Icons |
1 000 |
Complex image objects |
● Status/control |
With SIMATIC S7 |
● dynamic objects |
Diagrams, bar graphs, sliders, analog display, invisible buttons |
— Number of objects per project |
1 000 |
— Number per image |
10 |
● Methods |
Trend / profile |
● Limit value lines |
Yes |
● Number of bars per chart |
10 |
● Limit value lines |
Yes |
● alphanumeric fields |
300 |
● alphanumeric fields per image |
200 |
● numerical fields |
2 048 |
● numerical fields per image |
200 |
● Password errors |
2 048 |
● Number of slides per image |
10 |
● Number of analog indicators per image |
10 |
● Number of visible switches per project |
200 |
● visible switches per image |
200 |
● hidden switches per image |
200 |
● Number of status switches per project |
200 |
● Button status switches per image |
200 |
● Number of selector switches per project |
200 |
● Selector switches per image |
200 |
● Number of decade switches per project |
200 |
● Decade switches per image |
200 |
● Number of signal lamps per project |
200 |
● Signal lamps per image |
200 |
Attributes for dynamic objects |
● Color change |
Yes |
● X/Y movement |
Yes |
● Hide |
Yes |
Lists |
● Number of text lists per project |
500 |
● Number of text lists per image |
200 |
● Number of entries per text list |
256 |
● Number of graphics lists per project |
400 |
● Number of graphic lists per image |
200 |
● Number of entries per graphics list |
256 |
Archiving |
● Number of archives per device |
20 |
● Number of measuring points per project |
20 |
● Number of entries per archive |
10 000 |
● Message archive |
Yes |
● Process value archive |
Yes |
● Archiving methods |
|
— Sequential archive |
Yes |
— Short-term archive |
Yes |
● Memory location |
SD and MultiMediaCard |
— Ethernet |
Yes |
● Data storage format |
|
— CSV |
Yes |
● Online evaluation |
|
— via trends |
Yes |
Filters |
● cyclic |
Yes |
● Tolerance |
Yes |
● Change |
Yes |
Security |
● Number of user groups |
50 |
● Number of user rights |
32 |
● Password export/import |
Yes |
Logging through printer |
● Recording/Printing |
Alarms, report (shift report), color print, hardcopy |
Transfer (upload/download) |
● Transfer of configuration |
MPI/PROFIBUS DP, USB, Ethernet, automatic transfer recognition |
Process coupling |
● Connection to controller |
S5, S7-200, S7-300/400, TI 505, SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus) see chapter "System interfaces" |
● S7-1200 |
Yes |
● S7-1500 |
Yes |
● S7-200 |
Yes |
— PPI (point-to-point) |
Yes |
— PPI network |
Yes |
— MPI |
Yes |
— PROFIBUS DP |
Yes |
— Ethernet |
Yes |
● S7-300/400 |
Yes |
— MPI |
Yes |
— PROFIBUS DP |
Yes |
— PROFINET |
Yes |
● S5 |
Yes |
— PROFIBUS DP |
Yes |
● TI 505 |
Yes |
● Allen Bradley (DF1) |
Yes |
● Allen Bradley (DF485) |
Yes |
● Mitsubishi (FX) |
Yes |
● Mitsubishi (MP4) |
Yes |
● Telemecanique (Uni-Telway) |
Yes |
● OMRON (LINK/Multilink) |
Yes |
● Modicon (Modbus) |
Yes |
● GE-Fanuc (SNP) |
Yes |
Functions |
● TAB sequence |
Yes |
● Calculating functions |
Yes |
● Animate |
Yes |
Service tools/configuration aids |
● Backup/restore |
Yes |
● Simulation |
Yes |
● Device switchover |
Yes |
● Delta transfer |
Yes |
Expandability/openness |
● Open Platform Program |
Yes |
I/O / Options |
I/O devices |
Printer, barcode reader |
● MultiMediaCard |
Yes |
● SD card |
Yes |
● USB memory |
Yes |
Additional software components loadable |
Yes |
Dimensions |
Width of the housing front |
483 mm |
Height of housing front |
310 mm |
Mounting cutout/device depth (W x H x T) |
434 mm x 291 mm / 60 mm device depth |
Weights |
Weight (without packaging) |
4.95 kg |
other |
free hotline |
Yes |
Warranty period |
1 y |
last modified: |
25.09.2015 |